The Remeha R-Gen Combined Heat and Power (CHP) range is the sustainable solution to providing highly-efficient heat and power for applications with consistent heating and electricity.

The R-Gen NG converts gas into both electricity and heat in a single process at the point of use - operating at higher efficiency levels than traditional generation, delivering a primary energy saving of up to 30% and up to 20% reduction in emissions.

R-Gen 20/44 NG and 50/100 NG models can achieve outstanding total-fuel efficiencies of 103-104%, reducing greenhouse gas emissions by up to 60% and primary energy consumption by up to 40%.

  • Extremely efficient, lower operating costs, more sustainable operation
  • Low CO2 and NOx emissions – supports environmental legislation
  • Remote monitoring and control - Greater visibility
  • 20kWe and 50kWe condensing units - Achieve even higher efficiencies of up to 104%
  • Suitable for new build and existing buildings with year-round heat and electrical demands - Flexible solution to sustainable heat and power
  • Low noise 52 dBA max at 1m - Quiet operation
  • For single use or in conjunction with condensing boilers - Versatile solution to energy-efficient, low carbon heat and power generation

Technical Sales Managers

Our dedicated CHP Technical Sales Managers will be able to offer bespoke help and advice on Combined Heat and Power solutions

Paul Wilson - National Sales Manager - CHP
paul.wilson@remeha.co.uk

Area Technical Sales Manager Telephone Email
Scotland and North East
Stephen Lynch 07436 538 896 stephen.lynch@remeha.co.uk
Yorkshire and North West
Vacant
Midlands, South West, Wales
Mark Gibbons
07442 508 039 mark.gibbons@remeha.co.uk
London and South East
Vacant

 

LITERATURE FOR R-Gen NG CHP Range

Download literature and product documents for the entire R-Gen NG CHP Range by clicking the links below.

TECHNICAL INFORMATION

Click to download the technical specification for the R-Gen Gas CHP Range in PDF format

    DACHS G5.5(2) DACHS G5.0(2) (3) DACHS F5.5(2)
PERFORMANCE
Fuel Natural Gas Natural Gas Propane
Load % 100 100 100
Electrical Output(4) kWe 5.5 5.0 5.5
Electrical Efficiency Nett % 27 26 27
Electrical Efficiency Gross % 24 23 24
Thermal Output(5) kWt 14.7 14.6 14.3
Thermal Efficiency Nett % 72 74 72
Thermal Efficiency Gross % 65 67 65
Total Efficiency Nett % 99 100 99
Total Efficiency Gross % 89 90 89
Heat to Power Ratio 2.67 2.92 2.60
Power Performance Coefficient Ratio 0.37 0.34 0.38
Operation Type On/off On/off On/off
Operation   Condensing Condensing Condensing
Fuel Input(6) kW 22.5 19.6 20
Gas Rate m3/hr 2.1 1.9 0.76
ENGINE
Type Stroke 4 4 4
Cylinders Number 1 1 1
Service Intervals hrs 3500 3500 3500
Speed RPM 3000 300 300
ELECTRICAL
Voltage v 400 400 400
Frequency Hz 500 500 500
Own Use(7) kW 0.09 0.09 0.09
Generator Type Asynchronous Asynchronous Asynchronous
Grid Connection Type G83/2 G83/2 G83/2
Grid System Type TN-S TN-S TN-S
Circuit Breaker Type C C C
NOISE
Sound Pressure (1m)(9) db(A) 54 54 54
Sound Power (1m) db(A) 69 69 69
DIMENSIONS
Width mm 990 990 990
Depth mm 1070 1070 1070
Height mm 1000 1000 1000
SERVICE SPACE
Side mm 600 600 600
Front mm 600 600 600
Rear mm 350 350 350
WEIGHT
kg 530 530 530
EFFICIENCY CLASS
ErP(10) Banding A+++ A+++ A+++
CONNECTIONS
Exhaust DN 80 80 80
Flow inch 1" 1" 1"
Return inch 1" 1" 1"
Gas inch 1/2" 1/2" 1/2"
Condensate inch 1/2" 1/2" 1/2"
PRESSURES
System Working Pressure (Min) bar 1.1 1.1 1.1
System Working Pressure (Max) bar 3 3 3
CHP Safety Valve Fitted bar 3 3 3
Gas Pressure (Min) mbar 20 20 50
Gas Pressure (Max) mbar 24 24 54
PRESSURES
BREEAM NOx Emissions S02 mg/kWh 61.7  Zero TBC
Grid NOx Emission mg/kWh 617 617 617
Electrical mg/kWh 206.9 75.6 TBC
Thermal mg/kWh 300.1 117.4 TBC
COMBUSTION AIR
Mass kh/h 37 37 37
Volume Flow m3/hr On application On application On application
FLUE GAS
Waste Gas Mass (Wet) kg/h 40.8 40.8 40.8
Waste Gas Mass (Dry) kg/h On application On application On application
Waste Gas Volume (Wet) m3/hr 33 32 33
Waste Gas Volume (Dry) m3/hr 27 26 27

1. The R-Gen SenerTec Dachs range complies with the high efficiency criteria according to CHP law.

2. Minimum methane number: 35; includeing setting and nozzle adjustment on site.

3. Reduced exhaust gas emission.

4. According to DIN ISO 3046, measured at the generator terminals, values may vary depending on altitude, environmental conditions and conditions of use.

5. Values from type/component test report for a return temperature of 30°C with integrated condensing unit, maximum supply flow temperature 83°C, maximum flow return temperature 70°C.

6. Values from type/component test report for a return temperature of 60°C according to Hi, tolerance +/- 5%.

7. Tolerance +/- 10% at 230V~.

8. Sound power level at 1m distance according to DIN EN ISO 3744, in brackets minimum levels with special accessories.

9. Calculation according to EN 50465:2015 for Dachs packages with temperature controller.