The Gas 110 Eco provides maximum energy efficiency and the Remeha weather compensator options ensure the boiler closely the system demand. Conventional and room-sealed flue system capability enables the boiler to be sited almost anywhere within a building.

  • High-efficiency boiler up to 99% GCV - higher than average energy savings
  • Extremely compact - particularly suitable for retrofit applications
  • Low Class 5 NOx emission levels from 32mg/kWh (0% 02, dry) - low pollutant emissions meeting all environmental legislation
  • Premix gas burner and one-piece cast aluminium heat exchanger - clean, trouble-free operation
  • Cleanable heat exchanger - as with all Quinta models - Dry side can be examined and descaled. Cleaning tool and gaskets available
  • Modulating 18-100%, OT Open therm, Control 0-10V signal or volt free - advanced boiler and calorifier control for maximum efficiency 
  • Cascade/modular packages for up to six boilers - effective space saving solution for greater design flexibility
  • Ultra quiet operation less than 48 dBA - improved comfort
  • For use with Natural Gas and LPG (115kW requires a conversion kit) - flexible solution to energy saving heating
  • Digital diagnostic display and remote signalling options - easy operation and maintenance

LITERATURE FOR the gas 110 eco

Download all literature and product documents for the Gas 110 Eco by clicking the links below.

TECHNICAL INFORMATION

Click to download the technical specification for the Gas 110 in PDF format

 

GAS 110 65

GAS 110 115

PERFORMANCE

Nominal heat output central heating operation @ 80/60°C kW (min-max)*

12-61

16.6-107

Nominal heat output central heating operation @ 50/30°C kW (min-max)*

13.2-65

18.4-114

Nominal input (Hi) (min-max)

12.2-62

17.2-110.2

EFFICIENCY

SBEM seasonal efficiency GCV

96.3%

94.79%

Efficiency – full load 100% NCV

98.3%

97.1%

Efficiency – part load 30% NCV

108.9%

107.1%

Eco design useful efficiency @ 80/60°C (100% full load) GCV

88.6%

87.5%

Eco design useful efficiency @ 50/30°C (30% part load) GCV

98.1%

96.5%

Energy labelling seasonal space efficiency GCV

96%

N/a

ErPD efficiency rating

A

N/a

Annual energy consumption Gj

189

N/a

Gas connection size BSP inches

¾” male thread

¾” male thread

GAS

Standard fuel

Natural gas

Natural gas

Optional fuel adjustment – see installation & service manual

LPG (propane)

LPG (propane)
conversion kit required

Gas consumption NG m3/h

6.56

11.66

Max gas consumption LPG kg/h

4.82

8.56

Min/max gas inlet pressure NG mbar

17-40

17-40

Min/max gas pressure LPG mbar

25-60

25-60

Gas connection size BSP inches

¾” male thread

¾” male thread

FLUE (CONCENTRIC CONNECTION SUPPLIED AS STANDARD)

Flue diameter mm I/D

100

100

Air inlet diameter mm I/D

150

150

Min/max flue gas flow rate kg/h

20.5-104

28.9-186

Average flue gas temperature (75/60°C)

65

67.9

Residual fan duty PA

100

250

HYDRAULICS

Water content litres

6.5

7.5

Resistance @ 11°C ΔT mbar

580

830

Hydraulic resistance @ 20°C ΔT mbar

175

230

Nominal flow rate @11°C ΔT l/s

1.32

2.32

Nominal flow rate @ 20°C ΔT l/s

0.73

1.28

Minimum flow rate I/hr

240

350

Condensate connection

25mm OD

25mm OD

Connection size BSP

1¼” male thread

1¼” male thread

Standard operating temperature °C 

20-90*

20-90*

Max operating temperature °C

90*

90*

Max water temperature °C

110*

110*

Max water operating pressure bar

4

4

Min water operating pressure bar

0.8

0.8

Min water operating pressure bar open vented* (0V)

0.3

0.5

GENERAL

Dry weight kg

116

133

Dimension (WxHxD) (Includes flow/return and gas pipework)

600 x 1100 x 770

600 x 1322 x 700

NOx (Dry, 0% 02) Mg/kWh EN483/15420

32

35

Noise levels dB(A) at 1 metre

48

<>

Eco design sound power levels LWA indoors dB

49

N/a

Standby heat Loss kWh/24hr

0.125

0.131

ELECTRICAL

Nominal power supply

230 x 1Ph x 50hz

230 x 1Ph x 50hz

Power consumption W

88

213

Modulating input V dc

0-10

0-10

Fuse rating amps

6.3

6.3

Controls voltage

24 (max 4va)

24 (max 4va)

Insulation class IP

21

*Open vented option maximum operating temperature 75°C

  • Plus Dane Housing

    Sheltered housing scheme set to save £3,500 in annual gas bills from heating.

    Heating services contractor TBR 24/7 Ltd recommended replacing faulty boilers with three high efficiency Gas 110 Eco boilers.

You may be interested in...

ENGINEERING EFFICIENCY SINCE 1935